Listed Assembly Details |
Ultimate Uplift Resistance |
Deck: Minimum 22 ga., Type B steel
Insulation: Nominal 2 in. thick Styrofoam Deckmate Plus FA adhered to the deck with InstaStik applied in 3/4-in. to 1 in. beads spaced at 6 in. oc. Second layer of 2 in. thick Styrofoam Deckmate Plus FA insulation adhered to the first layer with InstaStik Adhesive applied in 3/4-in. to 1 in. bead spaced at 6 in. oc.
Cover Board: Nominal 1/4-in. thick DensDeck Prime adhered to the second insulation layer using InstaStik applied in 3/4-in. to 1 in. bead spaced at 6 in. oc.
Roof Covering: One layer of Code compliant asphalt felt ply-sheet hot-mopped to the cover board. |
270 psf |
Deck: Minimum 22 ga., Type B steel
Insulation: Nominal 2 in. thick Styrofoam Deckmate Plus FA adhered to the deck with InstaStik applied in 3/4-in. to 1 in. beads spaced at 12 in. oc. Second layer of 2 in. thick Styrofoam Deckmate Plus FA insulation was adhered to the first layer with InstaStik Adhesive applied in 3/4-in. to 1-in. bead spaced at 12 in. oc.
Cover Board: Nominal 1/4-in. thick DensDeck Prime was adhered to the second insulation layer using InstaStik applied in ¾-in. to 1 in. bead spaced at 12 in. oc.
Roof Covering: One layer of Code compliant asphalt felt ply-sheet hot-mopped to the cover board. |
120 psf |
Deck: Minimum 22 ga., Type B steel
Insulation: Nominal 2-in. thick Styrofoam Deckmate Plus FA adhered to the deck with InstaStik applied in 3/4-in. to 1 in. beads spaced at 12 in. oc. Second layer of 2 in. thick Styrofoam Deckmate Plus FA insulation adhered to the first layer with InstaStik Adhesive applied in 3/4-in. to 1 in. bead spaced at 12 in. oc.
Cover Board: Nominal 1/4-in. thick Securerock adhered to the second insulation layer using InstaStik applied in 3/4-in. to 1 in. bead spaced at 12 in. oc.
Roof Covering: One layer of Code compliant asphalt felt ply-sheet hot-mopped to the cover board. |
135 psf |
Deck: Minimum 22 ga., Type B steel
Cover Board: Minimum 5/8-in. DensDek adhered to the steel deck with InstaStik applied in 3/4-in. to 1 in. beads at 12 in. oc spacing.
Insulation (optional): Any thickness and combination of Code compliant polystyrene, polyiso, and/or high density wood fiberboard adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced 12 in. oc.
Roof Covering: Any fully adhered code compliant single-ply, hot mopped, or torch applied modified bitumen membrane, hot mopped or cold applied BUR |
105 psf |
Deck: Minimum 22 ga., Type B steel
Insulation: Minimum 3/4-in. thick perlite board adhered to the steel deck with InstaStik applied in 3/4-in. to 1 in. bead at 6 in. oc spacing.
Insulation (optional): Any thickness and combination of Code compliant polystyrene, polyiso, and/or high-density wood fiberboard adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced 12 in. oc.
Roof Covering: Any fully adhered Code compliant single-ply, hot mopped, or torch applied modified bitumen membrane system, hot mopped or cold applied built-up system. |
90 psf |
Deck: Minimum 22 ga., Type B steel
Insulation: ASTM C1289 compliant Polyiso with glass facers, any thickness, adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced 12 in. oc.
Insulation (optional): Any thickness and combination of Code compliant polystyrene, polyiso, and/or high-density wood fiberboard adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced 12 in. oc.
Roof Covering: Any fully adhered Code compliant single-ply, hot mopped, or torch applied modified bitumen membrane system, hot mopped or cold applied built-up system. |
100 psf |
Deck: Minimum 22 ga., Type B steel
Insulation: ¾ in. perlite board adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced 12 in. oc.
Insulation (optional): Any thickness and combination of Code compliant polystyrene, polyiso, and/or high density wood fiberboard adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced 12 in. oc.
Roof Covering: Any fully code compliant adhered single-ply, hot mopped, or torch applied modified bitumen membrane system, hot mopped or cold applied built-up system. |
60 psf |
Deck: Minimum 22 ga., Type B steel
Insulation: Minimum 1-1/2 in. thick Perforated DeckMate adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced at 12 in. oc spacing.
Cover board: Minimum 5/8-in. thick DensDeck adhered with InstaStik applied in 3/4-in. to 1 in. bead spaced at 12 in. oc.
Roof Covering: Carlisle SureWeld FleeceBACK 100 TPO adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced at 12 in. oc . |
165 psf |