Intertek Directory of Building Products

DuPont de Nemours, Inc -Insta Stik™ Quik Set Commercial Adhesive Company: DuPont de Nemours, Inc.

DuPont Insta Stik Quik Set Commercial Adhesive is a one-component, polyurethane adhesive used to attach various insulation boards to other insulations and to steel deck in BUR and single-ply roof systems.  

UPLIFT RESISTANCE
 
Listed Assembly Details Ultimate Uplift Resistance
Deck: Minimum 22 ga., Type B steel
Insulation: Nominal 2 in. thick Styrofoam Deckmate Plus FA adhered to the deck with InstaStik applied in 3/4-in. to 1 in. beads spaced at 6 in. oc. Second layer of 2 in. thick Styrofoam Deckmate Plus FA insulation adhered to the first layer with InstaStik Adhesive applied in 3/4-in. to 1 in. bead spaced at 6 in. oc. 

Cover Board: Nominal 1/4-in. thick DensDeck Prime adhered to the second insulation layer using InstaStik applied in 3/4-in. to 1 in. bead spaced at 6 in. oc. 

Roof Covering: One layer of Code compliant asphalt felt ply-sheet hot-mopped to the cover board.
270 psf
Deck: Minimum 22 ga., Type B steel
Insulation: Nominal 2 in. thick Styrofoam Deckmate Plus FA adhered to the deck with InstaStik applied in 3/4-in. to 1 in. beads spaced at 12 in. oc. Second layer of 2 in. thick Styrofoam Deckmate Plus FA insulation was adhered to the first layer with InstaStik Adhesive applied in 3/4-in. to 1-in. bead spaced at 12 in. oc. 

Cover Board: Nominal 1/4-in. thick DensDeck Prime was adhered to the second insulation layer using InstaStik applied in ¾-in. to 1 in. bead spaced at 12 in. oc. 

Roof Covering: One layer of Code compliant asphalt felt ply-sheet hot-mopped to the cover board.
120 psf
Deck: Minimum 22 ga., Type B steel
Insulation: Nominal 2-in. thick Styrofoam Deckmate Plus FA adhered to the deck with InstaStik applied in 3/4-in. to 1 in. beads spaced at 12 in. oc. Second layer of 2 in. thick Styrofoam Deckmate Plus FA insulation adhered to the first layer with InstaStik Adhesive applied in 3/4-in. to 1 in. bead spaced at 12 in. oc.

Cover Board: Nominal 1/4-in. thick Securerock adhered to the second insulation layer using InstaStik applied in 3/4-in. to 1 in. bead spaced at 12 in. oc. 

Roof Covering: One layer of Code compliant asphalt felt ply-sheet hot-mopped to the cover board.
135 psf
Deck: Minimum 22 ga., Type B steel
Cover Board: Minimum 5/8-in. DensDek adhered to the steel deck with InstaStik applied in 3/4-in. to 1 in. beads at 12 in. oc spacing.

Insulation (optional): Any thickness and combination of Code compliant polystyrene, polyiso, and/or high density wood fiberboard adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced 12 in. oc.

Roof Covering: Any fully adhered code compliant single-ply, hot mopped, or torch applied modified bitumen membrane, hot mopped or cold applied BUR
105 psf
Deck: Minimum 22 ga., Type B steel
Insulation: Minimum 3/4-in. thick perlite board adhered to the steel deck with InstaStik applied in 3/4-in. to 1 in. bead at 6 in. oc spacing.

Insulation (optional): Any thickness and combination of Code compliant polystyrene, polyiso, and/or high-density wood fiberboard adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced 12 in. oc.

Roof Covering: Any fully adhered Code compliant single-ply, hot mopped, or torch applied modified bitumen membrane system, hot mopped or cold applied built-up system.
90 psf
Deck: Minimum 22 ga., Type B steel
Insulation: ASTM C1289 compliant Polyiso with glass facers, any thickness, adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced 12 in. oc.

Insulation (optional): Any thickness and combination of Code compliant polystyrene, polyiso, and/or high-density wood fiberboard adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced 12 in. oc.

Roof Covering: Any fully adhered Code compliant single-ply, hot mopped, or torch applied modified bitumen membrane system, hot mopped or cold applied built-up system.
100 psf
Deck: Minimum 22 ga., Type B steel

Insulation: ¾ in. perlite board adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced 12 in. oc.

Insulation (optional): Any thickness and combination of Code compliant polystyrene, polyiso, and/or high density wood fiberboard adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced 12 in. oc.

Roof Covering: Any fully code compliant adhered single-ply, hot mopped, or torch applied modified bitumen membrane system, hot mopped or cold applied built-up system.
60 psf
Deck: Minimum 22 ga., Type B steel

Insulation: Minimum 1-1/2 in. thick Perforated DeckMate adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced at 12 in. oc spacing.

Cover board: Minimum 5/8-in. thick DensDeck adhered with InstaStik applied in 3/4-in. to 1 in. bead spaced at 12 in. oc.

Roof Covering: Carlisle SureWeld FleeceBACK 100 TPO adhered with InstaStik applied in 3/4-in. to 1 in. beads spaced at 12 in. oc .
165 psf
NOTES: 
1. Fire Classification of the roof system will be regulated by the Listing of the roof covering.
2. The Listing Report states the ultimate uplift resistance. The building designer must apply an appropriate safety factor.  

FLORIDA  PRODUCT APPROVAL
Report No. Product Covered    
FL No. 720 INSTA STIK Quik Set Insulation Adhesive
Listing Report Return to Search
Attributes
CriteriaANSI / UL 1897 (2015) Ed. 7
CSI CodeNOT APPLICABLE
Listing SectionROOFING MATERIALS
Spec ID68092
Design Documents
No Results
Public Documents
No Results