Firewalk Safe-T-Span Pultruded Grating is a light weight, corrosion resistant FRP composite grating manufactured with phenolic resin and engineered to meet the full requirements of ASTM F3059. It is commonly used for flooring, platforms and walkways where resistance to high temperatures and low smoke emissions is required. Firewalk grating is also designed for use in areas where conventional metallic grating would be subject to corrosion or impose a weight penalty
Firewalk Safe-T-Span Pultruded Grating is currently approved to ASTM F3059 at a thickness of 1.5-in. and bar spacing range of 1-in. to 1.5-in. on center.
FIRE RATINGS
Standard |
Rating |
ASTM F3059, Section 17 Fire Integrity |
Level 2
Maximum clear span 44" (1118 mm) |
ASTM F3059, Section 16 Surface Flammability (ASTM E84) |
Flame Spread Index ≤ 20
Smoke Developed Index ≤ 450 |
MATERIAL RATINGS
Standard |
Rating |
ASTM F3059, Section 8 Deflection Limits |
Met the requirements |
ASTM F3059, Section 9 Assembled Grating Ultimate Failure |
Met the requirements |
ASTM F3059, Section 10 Wheel Loading |
Met the requirements |
ASTM F3059, Section 11 Assembled Panel Impact Resistance |
Met the requirements |
ASTM F3059, Section 12
(ASTM D2047) |
Met the requirements |
ASTM F3059, Section 13
(ASTM D4060) |
Met the requirements |
ASTM F3059, Section 14
(ASTM D4329) |
Met the requirements |
ASTM F3059, Section 15
Saltwater Spray Test (ASTM B117-19) |
Met the requirements |