Intertek Directory of Building Products

Onyx Metals - ONX-150 and ONX 175 Steel and Aluminum Roof Panels Company: Onyx Metals Inc.

Metal roofing products by Onyx Metals, LLC, are roll-formed metal roof panels of 24 Ga. steel or 0.032 Aluminum as described below:

1-1/2" 24 Ga. Mechanical Seam, max. 16” wide roof panel (ONX-150)
1-1/2" 0.032 Aluminum Mechanical Seam, max. 16” wide roof panel (ONX-150)
1-1/2" 0.032 Aluminum Nailstrip, 19” wide roof panel (ONX-150SN)
1-3/4" 24 Ga. Snap-Lock, max. 16” wide roof panel (ONX-175)
1-3/4" 0.032 Aluminum Snap-Lock, max. 16” wide roof panel (ONX-175)

FIRE CLASSIFICATION - ASTM E108
Class ASTM E108 Class A
Slope: Unlimited
Deck Type: Combustible
Details:
  1. Minimum 15/32" AC grade, Group 1 Exterior Plywood
  2. One layer GAF VersaShield underlayment
  3. ONYX roof panels:
    1. ONX-150 24 Ga. Mechanical Seam, or
    2. ONX-175 24 Ga. Snap-Lock

FIRE CLASSIFICATION - ASTM E108
Class ASTM E108 Class A
Slope: Unlimited
Deck Type: Combustible
Details:
  1. Minimum 15/32" AC grade, Group 1 Exterior Plywood
  2. Two layers GAF VersaShield underlayment
  3. ONYX roof panels:
    1. ONX-150 0.032 Aluminum Mechanical Seam, or
    2. ONX-150SN 0.032 Aluminum Nailstrip, or
    3. ONX-175 0.032 Aluminum Snap-Lock

FIRE CLASSIFICATION – ASTM E108
Class ASTM E108 Class A
Slope: Unlimited
Deck Type: Noncombustible
Details:
  1. Noncombustible (steel or concrete) deck
  2. Any code-complying underlayment
  3. ONYX roof panels
    1. ONX-150 24 Ga. Mechanical Seam
    2. ONX-150 0.032 Aluminum Mechanical Seam
    3. ONX-150SN 0.032 Aluminum Nailstrip
    4. ONX-175 24 Ga. Snap-Lock
    5. ONX-175 0.032 Aluminum Snap-Lock

FIRE CLASSIFICATION - ASTM E108
Class ASTM E108 Class B
Slope: Unlimited
Deck Type: Combustible
Details:
  1. Minimum 15/32" AC grade, Group 1 Exterior Plywood
  2. One layer GAF VersaShield underlayment
  3. ONYX 0.032 Aluminum roof panels:
    1. ONX-150 0.032 Aluminum Mechanical Seam, or
    2. ONX-150SN 0.032 Aluminum Nailstrip, or
    3. ONX-175 0.032 Aluminum Snap-Lock
 
UPLIFT RESISTANCE – see below
WIND DRIVEN RAIN – see below
 
Rating Assembly Design
TAS 100 – Pass (no leakage)
TAS 125 - Class 90
Assembly 1: Onyx 150 0.032 Aluminum Nailstrip
  1. Roof deck: Min. 5/8" 4-ply CDX Plywood nailed to 2x wood joists spaced 24" max. o.c. with 8d ring-shank nails spaced 6" o.c.
  2. Underlayment: 30# asphalt saturated organic felt paper complying with ASTM D226 installed with max. 4" overlaps, attached per code.
  3. Roof panel: Onyx 150 0.032 Aluminum Nailstrip 19" Wide Roof Panel, male leg fastened with #10 x 1" pancake head screws spaced 3" o.c. Female leg snap fit over male leg.
  4. Sealant: Continuous bead of BOSS 585 sealant applied between male and female leg, except for roof corner conditions, use BOSS 400 sealant instead.
Assembly 2: Onyx 175 24 ga. Snaplock and Onyx 175 0.032 Aluminum Snaplock
  1. Roof deck: Min. 5/8" 4-ply CDX Plywood nailed to 2x nominal wood joists spaced 24" max. o.c. with 8d ring-shank nails spaced 6" o.c.
  2. Underlayment: 30# asphalt saturated organic felt paper, attached per code.
  3. Clips: 1-3/4” high x 3” long 20 Ga. galvanized steel clips spaced 12” o.c. and fastened using two #10 x 1” pancake head fasteners per clip. For roof corner conditions, clips are spaced 6” o.c.
  4. Roof panel: Onyx 175 24 Ga. or Onyx 175 0.032 Aluminum Snaplock, 16” Wide Roof Panel. Male leg secured with clips. Female leg snap-fit over male leg.
Assembly 3: Onyx 150 24 Ga. Mechanical Seam and Onyx 150 0.032 Aluminum Mechanical Seam
  1. Roof deck: Min. 5/8" 4-ply CDX Plywood nailed to 2x nominal wood joists spaced max. 24" o.c. with 8d ring-shank nails spaced 6" o.c.
  2. Underlayment: 30# asphalt saturated organic felt paper complying with ASTM D226, attached per code.
  3. Clips: 1-1/2” high x 3” long 24 Ga. galvanized steel clips spaced 12” o.c. and fastened using two #10 x 1” pancake head fasteners per clip. For roof corner conditions, clips are spaced 6” o.c.
  4. Roof panel: Onyx 150 0.032 Aluminum or Onyx 150 24 Ga. Mechanical Seam, 16” Wide Roof Panel. Male leg secured with clips. Female leg snap-fit over male leg.
  5. Sealant: Continuous bead of GEOCEL 4500 Sealant between male and female leg.



FLORIDA PRODUCT APPROVAL
Product Covered Report No.
Onyx 1-1/2" Nailstrip
Onyx 1-1/2" Standing Seam
Onyx 1-3/4" Snaplock
FL 42097
Listing Report Return to Search
Attributes
CriteriaFBC TAS 100 (1995)
CriteriaFBC TAS 125 (2003)
CriteriaASTM E108 (2020)
CSI Code07 41 13 Metal Roof Panels
Listing SectionROOFING MATERIALS
Spec ID72521
Design Documents
No Results
Public Documents
No Results