Intertek Directory of Building Products

Dynamo Polyurethane Systems Dynamo 500 and Dynamo ECO 2000 Spray-Applied Polyurethane Company: Dynamo Polyurethane Systems Inc Code Compliance Research Reports: CCRR-0491

Dynamo 500 and Dynamo ECO 2000 Spray-applied Polyurethane Insulation.

The insulations are two-component spray-applied polyurethane foam plastic, produced in the field by combining a polymeric isocyanate (A component) with a resin (B component). The insulation liquid components are supplied in 55-gallon drums and must be stored at temperatures between 50°F and 90°F. The A and B components have a shelf life of six months when stored in factory-sealed containers at these temperatures.

Dynamo 500 has a nominal density of 0.5 pcf. Dynamo ECO 2000 a nominal density of 2 pcf.

The insulations meet the requirements of Mandatory Testing and selected Optional Testing of ICC-ES Acceptance Criteria for Spray-applied Foam Plastic Insulation (AC377), for a low-density insulation as described in Code Compliance Research Report CCRR-0491.

FLAME SPREAD RATINGS
Test Standard          Flame Spread Index         Smoke Developed Index        
ASTM E84 25 or less 450 or less

FIRE RATINGS
Test Standard Configuration /
Details
Rating
NFPA 285 See CCRR-0491 Met requirements as configured
NFPA 286     See CCRR-0491     Met acceptance criteria of
    IBC Section 803.1.1.1 and         
IRC Section R302.9.4 as
configured
    ICC-ES AC377          
Appendix X
See CCRR-0491 Met requirements as
configured

CODE COMPLIANCE RESEARCH REPORT
   Evaluation Method              Building Code                       CCRR Number           
ICC-ES AC377
ICC 1100
2024, 2021, 2018 IBC
2024, 2021, 2018 IRC
2024, 2021, 2018 IECC
CCRR-0491
Listing Report Return to Search
Attributes
CriteriaNFPA 286 (2015)
CriteriaICC 1100 (2019)
CriteriaASTM E84 (2021a)
CriteriaNFPA 285 (2023)
CriteriaICC-ES AC377 (February 2023)
CSI Code07 21 00 Thermal Insulation
CSI Code07 21 19 Foamed-In-Place Insulation
Listing SectionBUILDING MATERIALS WITH SURFACE BURNING CHARACTERISTICS
Listing SectionFOAM PLASTIC INSULATION
Spec ID72542
Design Documents
No Results
Code Compliance Research Reports
Public Documents
No Results