Intertek Directory of Building Products

Lexington Manufacturing - 20 Minute Stile and Rail Flat or Raised Panel Door Company: Lexington Manufacturing, LLC

Product Covered/Description
Lexington Manufacturing - 20 Minute Stile and Rail Flat or Raised Panel Door Assembly with Hose Stream.

Category A Doors – No Additional Edge-Sealing System Required

Category B Doors – Additional Edge-Sealing System Required
A field applied intumescent edge seal (Category G) is required for Category “B” applications (both vertical edges and across the door head).  Can be frame applied or door edge applied - please consult listed intumescent edge seal manufacturer's installation instructions.  
 
Flat and Raised Panel (Proprietary Construction), Single Swing Fire Door for installation in 20 minute single locations (with hose stream). For use in any "Category C - Standard" frame or in any "Category C - Proprietary" frame in accordance with the door manufacturer's installation instructions.

Limitations*
Cylindrical Latch/Mortise Locks/Deadbolts (cylindrical, mortise, & interconnected)/Rim Type Fire Exit Devices/Surface Mounted Closers/Surface Mounted Protection Plates/Viewers/Mortised or Surface Mounted Door Bottoms.
Configuration/Maximum Size
Single Swing 3’-0” wide by 8’-0” tall
Standard Pair Not Allowed
Double Egress Not Allowed
*See manufacturer's installation instructions for additional information on Smoke & Draft control, size restrictions and limitations.

All doors listed in Category A or B are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.

All doors in this listing are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a serial number, and the Warnock Hersey Certification Mark and "UL 10C (Positive Pressure)/NFPA 252/ CAN/ULC S104".

Evaluated to the following
Unless otherwise noted, the product listed above in this section has been evaluated for conformance to the following standards:
  • UL 10C – Positive Pressure Fire Test of Door Assemblies
  • NFPA 252 – Fire Test of Door Assemblies
  • CAN/ULC S104 – Standard Method for Fire Test of Door Assemblies
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016) Ed. 3 (R:27 May 2021)
CriteriaNFPA 252 (2022)
CSI Code08 10 00 Doors and Frames
Fire Resistance20 Min w/Hose Positive Pressure
Listing SectionCATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID73386
SwingSingle Swing
Design Documents
No Results
Public Documents
No Results