Intertek Directory of Building Products

Forte 45-90 Minute Flush Wood Composite Door (NP CAN/ULC S104) Company: Forte Opening Solutions

Mineral Core Type, Swinging Flush Design Fire Door for installation in pairs in 90 minute locations (with Hose Stream).  For use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in accordance with the frame manufacturer's individual listing. 
 
Limitations*
Mortise or Cylindrical Latches with maximum 5” backset/Interconnecting Locks/Card Locks**/Surface-Mounted Vertical Rod fire exit devices/Concealed Vertical Rod fire exit devices/Rim-Type fire exit devices/Deadbolts/Flushbolts with extension up to a maximum of 18"/Pivot Hinges/Surface-Mounted or Concealed Stops/Surface-Mounted or Concealed Closers/Floor Closers/Magnetic Switch/Viewer/Vision Light Kit – Maximum 1296 sq. in./Surface-Mounted or Mortised Door Bottoms/Power Transfer Units/Raceways/Louvers/Edge-Guards/Kick Plates/Applied Mouldings
 
* See manufacturer’s installation instructions for additional information on Smoke and Draft Control, size restrictions, and limitations. 

**See Machining Information section under locks and latches for additional approvals.
Maximum Size of Openings:  

Pairs

 

Duration
Maximum    size
(w x h)
Swing  Latching  Metal Edge
(5")
Comments See below for conditions
90 8'0" by 8'0" Std Pair SVR    
4 Pt.
No None
90 8'0" by 8'0 Std Pair 3 Pt. latching Auto or manual flushbolts No Cylindrical or Mortise minimum 1/2" throw
90 8'0" by 8'0 Double Egress SVR    
4 pt.
No Must have top and bottom rod Hardware secured with sexbolts
90 8'0" by 8'0 Double Egress CVR/CVC
2 pt.
Yes 2,5
90 8'0" by 8'0" Std. Pair CVR 2 pt. Yes 1,2,5
90 8'0" by 9'3" Std. Pair SVR 4 pt. No Requires 6" stile C13 stile
90 8'0" by 9'0" Double Egress/Std Pair SVR 2 pt. or     4 pt. No Requires 6" stile C13 stile

Requires thermal pin door to door
60 8'0" by 8'0 Std. Pair SVR
2 pt.
No Requires thermal pin door to door
60 6'0" by 9'0" Std. Pair SVR/CVR 2 pt. Yes Requires thermal pin door to door
45 8'0" by 9'0 Std.
Pair
CVR/CVC/LBR
 
Yes Requires thermal pin door to door



Singles
 
Duration Maximum    size
(w x h)
Swing  Latching  Metal Edge
(5")
Comments
90 4'0" by 10'0" Single Cylindrical/Mortise No If CVR rod used must use 5" metal edge
60 4'0" by 10'0" Single Cylindrical/Mortise  No If CVR rod used must use 5" metal edge
45 4'0" by 10'0" Single Cylindrical/Mortise  No If CVR rod used must use 5" metal edge

CVR OPTIONS AND REQUIREMENTS FOR STILES AND RAILS
 
Options Device Mfg Rating Stile Top Rail  Bottom Rail Fire Pins
1 Adam Rite 3900 45-90  5" Tectonite 1-3/4" Tectonite 3-3/8" Tectonite Door to floor
2 Sargent WD-12 45-90 5" Tectonite 3-3/8" Tectonite 3-3/8" Tectonite As required
3 Monarch 45-90 5" Tectonite 3-3/8" Tectonite 3-3/8" Tectonite As required
4 Corbin Russwin/Yale 45-90 5" Tectonite 3-3/8" Tectonite 3-3/8" Tectonite As required
5 Von Duprin 45-90 5" Tectonite 3-3/8" Tectonite 3-3/8" Tectonite Door to door
6 Precision 45-90 5" Tectonite 3-3/8" Tectonite 3-3/8" Tectonite As required
7 Dorma 45-90 5" Tectonite 3-3/8" Tectonite 3-3/8" Tectonite As required
Note OS Lite may also be used in place of the Tectonite in the table above for a maximum door side of 4'-0" wide by 8'-0" tall.

Evaluated to the following...
This category includes doors evaluated without an edge-sealing system between the door and frame. 
 
Meeting edges of pairs may require an astragal or an edge-sealing system. Please refer to individual door listings.

These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.

Doors are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
 
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "CAN/ULC S104 or UL 10B".
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(b) (2008) (R2015)
CriteriaNFPA 252 (2017)
CSI Code08 10 00 Doors and Frames
CSI Code08 14 00 Wood Doors
Fire Resistance45 Min Neutral Pressure
Fire Resistance90 Min Neutral Pressure
Fire Resistance60 Min Neutral Pressure
Listing SectionDOORS
Spec ID74233
SwingSingle Swing
SwingStandard Pairs
SwingDouble Egress
Design Documents
No Results
Public Documents
No Results