Mineral Core Type, Swinging Flush Design Fire Door for installation in pairs in 90 minute locations (with Hose Stream). For use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in accordance with the frame manufacturer's individual listing.
Limitations*
Mortise or Cylindrical Latches with maximum 5” backset/Interconnecting Locks/Card Locks**/Surface-Mounted Vertical Rod fire exit devices/Concealed Vertical Rod fire exit devices/Rim-Type fire exit devices/Deadbolts/Flushbolts with extension up to a maximum of 18"/Pivot Hinges/Surface-Mounted or Concealed Stops/Surface-Mounted or Concealed Closers/Floor Closers/Magnetic Switch/Viewer/Vision Light Kit – Maximum 1296 sq. in./Surface-Mounted or Mortised Door Bottoms/Power Transfer Units/Raceways/Louvers/Edge-Guards/Kick Plates/Applied Mouldings
* See manufacturer’s installation instructions for additional information on Smoke and Draft Control, size restrictions, and limitations.
**See Machining Information section under locks and latches for additional approvals.
Maximum Size of Openings:
Pairs
Duration |
Maximum size
(w x h) |
Swing |
Latching |
Metal Edge
(5") |
Comments See below for conditions |
90 |
8'0" by 8'0" |
Std Pair |
SVR
4 Pt. |
No |
None |
90 |
8'0" by 8'0 |
Std Pair |
3 Pt. latching Auto or manual flushbolts |
No |
Cylindrical or Mortise minimum 1/2" throw |
90 |
8'0" by 8'0 |
Double Egress |
SVR
4 pt. |
No |
Must have top and bottom rod Hardware secured with sexbolts |
90 |
8'0" by 8'0 |
Double Egress |
CVR/CVC
2 pt. |
Yes |
2,5 |
90 |
8'0" by 8'0" |
Std. Pair |
CVR 2 pt. |
Yes |
1,2,5 |
90 |
8'0" by 9'3" |
Std. Pair |
SVR 4 pt. |
No |
Requires 6" stile C13 stile |
90 |
8'0" by 9'0" |
Double Egress/Std Pair |
SVR 2 pt. or 4 pt. |
No |
Requires 6" stile C13 stile
Requires thermal pin door to door |
60 |
8'0" by 8'0 |
Std. Pair |
SVR
2 pt. |
No |
Requires thermal pin door to door |
60 |
6'0" by 9'0" |
Std. Pair |
SVR/CVR 2 pt. |
Yes |
Requires thermal pin door to door |
45 |
8'0" by 9'0 |
Std.
Pair |
CVR/CVC/LBR
|
Yes |
Requires thermal pin door to door |
Singles
Duration |
Maximum size
(w x h) |
Swing |
Latching |
Metal Edge
(5") |
Comments |
90 |
4'0" by 10'0" |
Single |
Cylindrical/Mortise |
No |
If CVR rod used must use 5" metal edge |
60 |
4'0" by 10'0" |
Single |
Cylindrical/Mortise |
No |
If CVR rod used must use 5" metal edge |
45 |
4'0" by 10'0" |
Single |
Cylindrical/Mortise |
No |
If CVR rod used must use 5" metal edge |
CVR OPTIONS AND REQUIREMENTS FOR STILES AND RAILS
Options |
Device Mfg |
Rating |
Stile |
Top Rail |
Bottom Rail |
Fire Pins |
1 |
Adam Rite 3900 |
45-90 |
5" Tectonite |
1-3/4" Tectonite |
3-3/8" Tectonite |
Door to floor |
2 |
Sargent WD-12 |
45-90 |
5" Tectonite |
3-3/8" Tectonite |
3-3/8" Tectonite |
As required |
3 |
Monarch |
45-90 |
5" Tectonite |
3-3/8" Tectonite |
3-3/8" Tectonite |
As required |
4 |
Corbin Russwin/Yale |
45-90 |
5" Tectonite |
3-3/8" Tectonite |
3-3/8" Tectonite |
As required |
5 |
Von Duprin |
45-90 |
5" Tectonite |
3-3/8" Tectonite |
3-3/8" Tectonite |
Door to door |
6 |
Precision |
45-90 |
5" Tectonite |
3-3/8" Tectonite |
3-3/8" Tectonite |
As required |
7 |
Dorma |
45-90 |
5" Tectonite |
3-3/8" Tectonite |
3-3/8" Tectonite |
As required |
Note OS Lite may also be used in place of the Tectonite in the table above for a maximum door side of 4'-0" wide by 8'-0" tall.
Evaluated to the following...
This category includes doors evaluated without an edge-sealing system between the door and frame.
Meeting edges of pairs may require an astragal or an edge-sealing system. Please refer to individual door listings.
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
Doors are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "CAN/ULC S104 or UL 10B".