Intertek Directory of Building Products

Forte 45-90 Minute with Skamol Core CAT A Door Company: Forte Opening Solutions

PRODUCT TYPE 
Mineral Core Type, Swinging flush door for installation in and up to 45, 60 and 90 minute locations. For use in listed (3-sided) 16-gauge welded steel frames meeting UL63 or as per frame manufacturer’s listing(s). 
Configuration                              Maximum Size
Single Swing                                   4’0” x 8’0”
Standard Pairs                                8’0” x 8’0”
Double Egress Pairs                       Not Allowed

Door with Transom (Overall Size)      4’0” x 8’0”
Limitations*: 
Mortise or Cylindrical Latches with maximum 5” backset / Mortise Fire Exit Devices / Surface-Mounted Vertical Rod Fire Exit Devices / Rim-Type Fire Exit Devices / Concealed Vertical Rod Fire Exit Devices / Deadbolts / Surface Bolts / Automatic Flush Bolts / Surface-Mounted Closers / Concealed Closer Arms (45 and 60) / Surface-Mounted Protection Plates / Plant-Ons / Viewer / Louver / Vision Light Kit – Maximum 1296 sq. in. (45 Minutes only) / Vision Light Kit – Maximum 100 sq. in. (60 and 90 Minutes) / Surface-Mounted Door Bottoms / Metal Edge or Astragal Not Required up to 60 Minutes / 5" Metal Edge Required on CVR / 1" Metal Edge Required on 90 Minute Pair / Temperature Rise - 250°F at 30 Minutes. 
* See manufacturer’s installation instructions for additional information on Smoke and Draft Control, size restrictions, and limitations.
 
Evaluated to the following...
This category includes doors evaluated without an edge-sealing system between the door and frame. It also includes doors evaluated with a sealing system incorporated (concealed or visible) into the edge of the door by the licensed manufacturer or machining distributor.
 
Meeting edges of pairs may require an astragal or an edge-sealing system. Please refer to individual door listings.
 
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
 
All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
 
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UL 10C".
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016)
CriteriaUL 10(b) (2008) (R2015)
CriteriaNFPA 252 (2017)
CSI Code08 10 00 Doors and Frames
Fire Resistance45 Min Neutral Pressure
Fire Resistance60 Min PP Category A Door
Fire Resistance90 Min Neutral Pressure
Fire Resistance90 Min PP Category A Door
Fire Resistance45 Min PP Category A Door
Fire Resistance60 Min Neutral Pressure
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID74318
SwingSingle Swing
SwingStandard Pairs
Temperature Rise@ 30 Min = 250° F MAX Where Lites Do Not Exceed 100 IN2
Design Documents
No Results
Public Documents