Safti First EZ-ARC-FR-120 2 hour rated wall assembly Company: SAFTI FIRST

PRODUCT DESCRIPTION

SAFTI FIRST SuperLite II 120 Fire Rated Wall Assembly is composed of a multi-layered glass panel laminated together by a fire resistive intumescent interlayer.  Glass panels are 3-1/8 in. (53mm) thick.  The EZ-ARC-FR Framing system main components include tubular steel, gypsum boards, composite framing, snap on covers, and Insulation. See manufacturing section for additional construction and installation details. 

RATINGS

 
SF/GG 120-06
ASTM E119 - (2022) 2 hrs
EZ-ARC-FR-120 SuperLite glazing  
Max Individual Panel Dimensions
Maximum Allowable Panel Area 10400 sq. in.
Maximum Allowable Panel Width 130 in.
Maximum Allowable Panel Height 130 in.
Minimum Glazing Thickness 3-1/8 in.
Listing Report Return to Search
Attributes
Criteria16 CFR 1201 (2008)
CriteriaUL 263 (2011)
CriteriaCAN / ULC S101 (2014)
CriteriaASTM E119 (2015)
CriteriaUL 263: 2011 Ed. 14 (R2020)
CriteriaASTM E119 (2022)
CSI Code08 80 00 Glazing
Listing SectionGLAZING/GLASS
Spec ID74441