FIRE DOOR FRAMES
CATEGORY C - PROPRIETARY FRAMES for installation in 20 Minutes masonry or aerated concrete wall openings.
PRODUCT COVERED
Starlink 20 Minutes Fire Rated PVC Door Frame
Frame Model: 4 9/16
PRODUCT DESCRIPTION
Frame type: CATEGORY C - PROPRIETARY FRAMES
Type of wall for use with: Aerated concrete wall or masonry wall
Frame stop: 12.7 mm high at header and jamb edges
| Maximum Size of Openings: |
Singles - 920 mm wide x 2444 mm high
Pairs - Not Allowed
Double Egress – Not Allowed |
| Minimum Jamb Depth: |
116 mm |
For use with Starlink 20 Minutes Fire Rated Fiberglass Door with Hose Stream (Model FS202).
The two door jambs and the head jamb were assembled and fastened by three M4 x 50 mm self-tapping screws. The frame was installed in an aerated concrete block wall opening by four (4) sets of steel bars and nails on each frame jamb, spaced 550 mm and with a distance of 150 mm from top and bottom of frame jamb. The clearances between the door frame and the wall were filled with mineral wool and clad with quick-setting cement on both sides.
Frames Evaluated to the Following:
Unless otherwise noted, assemblies in this section have been tested to the following standards:
CAN/ULC S104, Standard Method for Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UL-10B, Standard for Fire Tests of Door Assemblies;
UL-10C, Standard for Positive Pressure Fire Tests of Door Assemblies;
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Standard for Fire Doors and Other Opening Protectives;
Manufacturer's Installation Instructions;
All frames are identified by either a label or embossed marking bearing the wording "Fire Door Frame" and the Intertek WH Certification Mark. Frames rated for less than 3 hours also bear the time interval.