MPI KY, LLC - 20-90 Min Steel Fire Door Frame w/Transom Panels & Transom and/or Side Lites Company: MPI KY LLC

Pressed Steel Door Frame (16 gauge) (Welded Up) with Preassembled Steel-Faced Transom and/or Side Panels (450°F 30 minute Temp. Rise) for installation in 20 minute up to and including 1-1/2 hour locations in steel/wood stud drywall or masonry openings.
 
Limitations
45 Minute Openings - Glazed 1/4" wired glass is permitted as full or raised side lights and transoms, subject to a maximum clear view area of 1,296 sq.in. with no clear dimension to exceed 54" using 1/2" stops. For glazed openings of 500 sq.in. or less, 5/8" stops may be used. 20 Minute Openings - Glazed 1/4" wired glass is permitted as full or raised side lights and transoms with 5/8" stops, subject to a maximum clear view area of 5,567 sq.in. with clear width not to exceed 58-3/4" and clear height not to exceed 116-3/4". Labeled 1/4" wire Glass may be installed at one Rabbet and 1" Glass at opposite Rabbet.
 
Maximum Overall Dimensions: 136" wide x 144" high
Minimum Throat Opening: 3-1/2"
Maximum Door Opening Sizes: Singles- 4' 0" wide x 8' 0" high
Pairs- 8' 0" wide x 8' 0" high
Maximum Steel-Faced Panel Size: 3072 sq.in. with no dimensions to exceed 96"
Fabrication Standard: UL-63
Evaluated to the following...
Unless otherwise noted, assemblies in this section have been tested to the following standards:
ASTM-E152, Methods of Fire Tests of Door Assemblies
CAN4-S104(ULC-S104), Standard Method for Fire Tests of Door Assemblies
CSFM-43.7, Methods of Fire Tests of Door Assemblies
NFPA-252, Standard Methods of Fire Tests of Door Assemblies
UBC-7-2-94, Uniform Building Code
UL-10(b), Fire Tests of Door Assemblies
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows
Manufacturer's Instructions
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark. Frames rated for less than 3 hours also bear the time interval. Frame labels that do not include a time interval are rated for 3 hours.
Listing Report Return to Search
Attributes
CriteriaUBC 7-2 (1994)
CriteriaUL 10(b) (1997)
CriteriaNFPA 252 (1999)
CriteriaCAN4 S104 (1985)
CriteriaUL 10(b) 2008 (R2009)
CriteriaNFPA 252 (2012)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance20 Min NP Fire Doorframe with Transom and/or Sidelite
Fire Resistance45 Min NP Fire Doorframe with Transom and/or Sidelite
Fire Resistance60 Min NP Fire Doorframe with Transom and/or Sidelite
Fire Resistance90 Min NP Fire Doorframe with Transom and/or Sidelite
Listing SectionCATEGORY C - PROPRIETARY FRAMES
Spec ID75164
SwingSingle Swing
SwingStandard Pairs
SwingDouble Egress
Temperature Rise@ 30 Min = 450° F MAX Where Lites Do Not Exceed 100 IN2