MPI KY, LLC - 45-90 Min Acoustical and Lead-Lined Steel Fire Doors
Company: MPI KY LLC
FIRE DOORS - NEUTRAL PRESSURE
Steel Acoustical and Lead-Lined Fire Doors (16 or 18 gauge cold rolled steel) for installation in 45 - 90 minute locations.
Limitations
Mortise or Cylindrical Latches with a maximum 5" backset / Flushbolts / Astragals / Vision Panels.
| Singles |
4'0" wide x 9'0" high |
| Standard Pairs |
8'0" wide x 9'0" high
(4'0" wide each leaf) |
Evaluated to the following...
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
ASTM-E152, Methods of Fire Tests of Door Assemblies
CSFM-43.7, Methods of Fire Tests of Door Assemblies
CAN4-S104(ULC-S104), Standard Method for Fire Tests of Door Assemblies
NFPA-252, Standard Methods for Fire Tests of Door Assemblies
UBC-7-2-94, Uniform Building Code
UL-10(b), Fire Tests of Door Assemblies
and are installed in accordance with the following:
NFPA-80, Fire Doors and Windows
Manufacturer's Instructions.
All assemblies are identified by a label or marking bearing the wording, "Listed (Product)", a time interval, temperature rise (if applicable), a serial number and the WHI Certification Mark.
(Unless otherwise specified, all Fire Doors have a nominal thickness of 1-3/4".)