DKS 1/3-3 Hour Steel-Stiffened Steel Fire Doors PP Model 1300 Company: DKS Steel Door and Frame Systems, Inc.

CATEGORY A DOORS-NO ADDITIONAL EDGE-SEALING REQUIRED
Hollow Metal (12, 14, 16, 18, 20 gauge) Vertical Stiffened, Swinging Flush Design Fire Door for installation singly or pairs, including double egress in 1/3 Hour to 3 Hour locations. For use in listed (3-sided) 16 gauge welded steel frames meeting ANSI-A155.1/UL-63 or as per manufacturer's listings.
Limitations:
Mortise or Cylindrical Latches with up to 5" Backset/Surface or Concealed Vertical Rod, including Top Rod Only/Rim Fire Exit Hardware/Viewers/Surface Mounted Closers/Concealed Closer Arms/Surface Bolts/Surface Mounted Protection Plates/Viewer/Louver/Surface Mounted or Mortised Door Bottoms/Vision Light Kit - Maximum 1296 sq.in. for 20/45 minute (or maximum tested by manufacture of glass) maximum tested by manufacture of glass for 60 minute to 3 hour. Astragal for Pairs and Double Egress Pairs is optional. Temperature Rise greater than 650°F @ 30 minutes.
 
 
Configuration Maximum Size*
Single 4'0" wide x 10'0" high
Pairs 8'0" wide x 10'0" high
Double Egress 8'0" wide x 10'0" high
 
*See manufacturer's installation instructions for additional information on Smoke and Draft Control, size restrictions and limitations.

 
 
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL 10C".
 
Listing Report Return to Search
Attributes
CriteriaUL 10(c) (1998)
CriteriaUBC 7-2 (1997)
CriteriaNFPA 252 (1999)
CriteriaCAN4 S104 (1985)
CriteriaUL 10(c) (2009)
CriteriaCAN / ULC S104 (2010)
CSI Code08 11 00 Metal Doors and Frames
CSI Code08 11 13 Hollow Metal Doors and Frames
Fire Resistance60 Min PP Category A Door
Fire Resistance3 Hour PP Category A Door
Fire Resistance90 Min PP Category A Door
Fire Resistance45 Min PP Category A Door
Fire Resistance20 Min w/Hose Positive Pressure
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED