Intertek Directory of Building Products

TGP - Fireframes® Curtainwall Series - Fully Glazed Steel Partition Assembly - 180 Minutes - EN 1364-1 Company: Technical Glass Products, Inc.

Product Covered
TGP - Fireframes® Curtainwall Series - Fully Glazed Steel Partition Assembly - 180 Minutes - EN 1364-1

Product Description
Fully Glazed Steel Partition Assembly - 

The partition mullions and transoms are made using range of steel TGP Fireframes® Curtainwall series profiles (45mm and 60mm wide, depth varies)


The partition is glazed with FireLite® (5mm thick), FireLite® NT (5mm thick) or FireLite® IGU (Nominal 25mm thick with tempered glass pane). The glazing panes are supported on setting blocks and secured in place with steel pressure plates covered with aluminium caps. Ceramic glazing tape is used between the glazing and mullion/transom and also between the glazing and pressure plates. 1.5mm thick Intumescent tape is placed around the glazing perimeter of IGU panes. 

Maximum Sizes:
Tested Assembly Size - 3000mm x 3000mm (w x h)

Maximum Glass size allowed:
Maximum width - 1115mm at 2134mm height
Maximum height - 2543mm at 936mm width
Maximum area - 2.38 sq. m
Or
Maximum width - 1001mm at 2457mm height
Maximum height - 2926mm at 841mm width
Maximum area - 2.46 sq. m
Or
Maximum width - 2041mm at 512mm height
Maximum height - 610mm at 1713mm width
Maximum area - 1.045 sq. m

FIRE RATINGS
The fully glazed partition assembly has been tested according to EN 1364-1:2015 standard and qualifies for the following ratings:
Criterion Rating
Integrity (E) 180 Minutes

Note 1: For E180 rating, 20% extension in height is allowed above the tested height and the width of the assembly can be extended infinitely by replication of the tested assembly. 
Note 2: The product noted above also meets the requirements of BS 476 Part 20(1987) and BS 476 Part 22(1987).
Note 3: Glazing panes are allowed to be installed using Silicone gaskets for up to 30 minutes fire rating. Gasket reference given below:
300381S - Pressure Plate Gasket
306130S - 45mm CW Back Gasket
305170S - 60mm CW Back Gasket
Listing Report Certificate of Compliance Return to Search
Attributes
Certificate Date of ExpiryDecember 31, 2025
Certificate Date of Initial RegistrationDecember 17, 2019
Certificate NumberWHI19-34918804
CriteriaBS 476 Part 22 (1987)
CriteriaEN 1364-1 (2015)
CriteriaBS 476 Part 20 (1987)
CSI Code10 22 00 Partitions
Fire Resistance180 Minute Fire Rated
Listing SectionPARTITION
Spec ID77874
Design Documents
No Results
Public Documents