Intertek Directory of Building Products

Steelcraft Paladin Outswing Pair Steel Door and Frame Assembly ICC 500-2020 Company: Steelcraft Manufacturing / Schlage Lock Company LLC

Steelcraft Paladin Outswing Pair Steel Door and Frame Assembly

ICC 500-2020 PRODUCT ASSEMBLY & RATINGS

Tornado-resistant steel door and frame assemblies with design pressure and debris impact ratings. 

This listing is for wind pressure and impact resistance only. Fire resistance, when required by Section 603 of ICC 500-2020, is outside the scope of this listing. Assemblies required to be fire-resistance-rated shall also bear the label of a separate fire listing to the applicable standard(s).

In accordance with Section 507.3 of ICC 500-2020, operating hardware located on the unprotected side of the assembly shall be not susceptible to unintended unlatching by debris impact. Once engaged for storm shelter use, such operating hardware shall be locked, disabled, or inactive. Compliance with this requirement shall be confirmed by the Authority Having Jurisdiction.
 
Paladin Steel Door and Frame - Pair Outswing
Assembly Type Permitted Size Design
Tornado Pressure
Impact Rating
Standard Pair
Outswing

 
Frame: Min:76 in. × 82 in.
            Max:100 in.×98 in.
Door:  Min: 72 in. × 80 in.
           Max: 96 in. × 96 in.
± 252 psf 15-lb 2×4 Missile
@ 100 mph
Configuration     Door: Steelcraft  PW14 with additional 1/2- x 1-1/2- x 1/8-inch steel channel reinforcement in latch edge of door
Frame: Steelcraft FP14 with 10-gauge auxiliary stops
Latching Hardware (4 point): Von Duprin, WS-T 98/9927 Series Exit Device (377T-NL, -2, and -ESL trim options permitted)
Hinges: Ives  5BB1HW, 5BB1HWNRP
Door Closer: Surface mounted to unprotected side of door with screws.
        LCN 4000T, 4010, 4010T, 4020, 4020T, 4030, 4030T, 4040XP, 4040XPT,
        4050, 4110, 4110T
        LCN 4040SE, 4310ME (electronic)
        LCN 9542, 9553 (auto-operators)
Protection Plate: Limited to unprotected side of door. Ives 8400, 8200
Electric Power Transfer: Von Duprin EPT-2, EPT-10
Door Position Switch: Limited to top and hinge edge of door.
          Schlage 679-05 (round), 7764
          Sentrol 1076, 1078 (round), 2757
          Securitron MSS-1
Floor & Wall Stops: Ives FS495 (surface-applied to unprotected side of door)
Accessories not evaluated: Overhead Stops, Thresholds, Magnetic Locks, Weatherstrips, Door Bottoms, Door Viewers, Vision Kits. 
Listing Report Certificate of Compliance Return to Search
Attributes
Certificate Date of ExpiryDecember 31, 2026
Certificate Date of Initial RegistrationFebruary 4, 2025
Certificate NumberWHI20-20329328
CriteriaICC 500 (2020)
CSI Code08 11 00 Metal Doors and Frames
Listing SectionWINDSTORM - SWING DOOR ASSEMBLIES
Spec ID78310
Windload/StructuralTornado Resistance
Design Documents
No Results
Public Documents