PRODUCT DESCRIPTION
Product |
Direct Vent Gas Fireplace Heater |
Brand Name |
Mendota |
Description |
The model 360 FireIn Direct Vent Gas Stove is constructed of sheet steel. The outer dimensions are 24.75-in wide x 20.375-in deep x 28.75-in tall.
The model 360 FireIn is Direct Vent Gas Stove suitable for use with natural gas or propane but is factory installed for use with natural gas. A gas appliance conversion kit is provided to convert the fireplace to propane.
This model features an automatic intermittent/standing pilot ignition system. A remote control is provided with the appliance to turn the fireplace off and on.
The 360 FireIn may be installed in a manufactured home (USA only) or mobile home aftermarket installation. |
Models |
360 FireIn |
Model Similarity |
None |
Ratings |
120V, 60Hz, 3.5A |
APPLIANCE RATINGS
|
NATURAL GAS |
PROPANE |
Model |
360 FireIn |
Input rating(Btu/hr) 0-610 m |
35,500 |
35,500 |
Input rating(Btu/hr) 610-1370 mm |
35,500 |
35,500 |
Minimum input (Btu/hr) 0-1370 m |
9,272 |
11,280 |
Orifice Size(DMS) 0-610 m |
Left-#51, Right-#52, Pan-#50 |
Left-#60, Right-#62, Pan-#58 |
Orifice Size(DMS) 610-1370 m |
Left-#51, Right-#52, Pan-#50 |
Left-#60, Right-#61, Pan-#58 |
Manifold pressure (in. w.c./kPa) normal |
3.5/0.87 |
10.0/2.50 |
Manifold pressure (in. w.c./kPa) reduced |
1.6/0.40 |
6.4/1.59 |
Manifold pressure (in. w.c./kPa) 610-1370m |
4.4/1.2 |
11.9/2.96 |
Minimum inlet pressure (in. w.c./kPa |
5/1.24 |
11.0/2.74 |
Air shutter settings (in) |
1/8”, 1/8”, 3/8” |
½”, ½”, ½” |
VENTING INFORMATION
Any combination of rise and run may be used if it is within the boundaries indicated below. The total vent length shall not exceed 40 feet. Refer to the Owner’s Manual for more details on the permissible venting configurations.
VENTING |
Vent Type |
Co-axial |
Vent Size |
4” x 6 5/8” |
Max. Vertical Length |
40’ |
Min. Vertical Length |
10’ |
Max. Horizontal Length |
20’ |
Min. Horizontal Length |
2’ |
Max. Horizontal Length at Min. Vertical Length |
2’ |
Min. Vertical Length at Max. Horizontal Length |
4’ |
Max. Number of 90° Elbows |
4 |
VENT MANUFACTURERS |
Duravent |
DirectVent Pro Series |
CLEARANCES TO COMBUSTIBLE CONSTRUCTION
CLEARANCES |
Side |
16-in/406 mm |
Back |
3-in/76 mm |
Min. Ceiling Height |
66-in/1676 mm |
Corner |
5-in/127 mm |
VENTING SYSTEM CLEARANCES |
Top of Horizontal Vent |
3-in/76 mm |