AADG - Series MX1100LS, 1200, 1600, 1800 3-Hour Polystyrene Core Steel Fire Door Company: AADG, Inc

PRODUCT COVERED

Series MX1100LS, 1200, 1600, 1800 Fire Door

PRODUCT DESCRIPTION

Foam or Honeycomb Core Steel Fire Doors for installation Singly or in Pairs in 3 hour positive pressure assemblies, with temperature rise greater than 650°F at 30 minutes.          

Limitations
Configuration Maximum Size
Single Swing 4’-0” wide by 8’-0” tall by 1 3/4” thick
(1,208 mm by 2,416 mm by 45 mm)
Standard Pairs 8’-0” wide by 8’-0” tall by 1 3/4” thick
(4’-0” wide by 8’-0” tall each leaf)
(2,416 mm by 2,416 mm by 45 mm)
Double Egress Not Allowed

Vision Panels: maximum 1296 infor 20 and 45 minute locations; 100 in2 for 60 and 90 Minute locations. Glazing kit for light kits requires use of minimum 18 ga. steel channel reinforcement attached to both faces around the vision panel cutout.

Louvers: maximum 576 in2 (24" x 24") for up to 90 Minute locations. Requires the use of minimum 18 ga. steel channel reinforcement attached to both faces around the louver cutout.

Evaluated to the following...

This category includes doors evaluated without an edge-sealing system between the door and frame. It also includes doors evaluated with a sealing system incorporated (concealed or visible) into the edge of the door by the licensed manufacturer or machining distributor.

Meeting edges of pairs may require an astragal or an edge-sealing system. Please refer to individual door listings.

These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.

All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.

All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and UL 10C".


 
Listing Report Return to Search
Attributes
CriteriaUL 10(c) (1998) (R2001)
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaNFPA 252 (2022)
CSI Code08 10 00 Doors and Frames
Fire Resistance3 Hour PP Category A Door
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID79538
SwingSingle Swing
SwingStandard Pairs
Temperature Rise@ 30 Min > 650° F