Wood core type (particleboard) routed simulated panel, swinging fire doors for installation in single swing applications in 20 minute locations (with hose stream). These doors are eligible for use in any "Category C - Standard Frames” in accordance with the frame manufacturer's individual listing(s). A field applied edge graphite based sealing system is required (1/2" wide minimum). Refer to the door manufacturer's installation instructions for edge sealing system requirements.
Limitations*
Cylindrical with a maximum backset of 2 3/4” and minimum bolt throw of 1/2”/Deadbolts/Butt Hinges/Continuous Hinges/Rim Exit Device/Surface-Mounted Vertical Rod/Surface Mounted Closer/Surface Mounted Door Bottoms.
*See manufacturer’s installation instructions for additional information of Smoke and Draft Control, size restrictions, and limitations.
Configuration/Maximum Sizes |
Single Swing |
3’-0” wide by 6’-8” tall |
Standard Pair |
Not Allowed |
Double Egress Pair |
Not Allowed |
Evaluated to the following:
Unless otherwise noted, the product listed above in this section has been evaluated for conformance to the following test standards:
- UL 10C – Positive Pressure Fire Test of Door Assemblies
- NFPA 252 – Fire Test of Door Assemblies
- CAN/ULC S104 – Standard Method for Fire Test of Door Assemblies