Intertek Directory of Building Products

Pemko Meeting Edge and Perimeter Gaskets – Category H and J Gaskets Company: Pemko Manufacturing Company

Pemko 297_PK (MS), 303_PK (MS), 305_N (MS), and 316_PK (MS) meeting edge gaskets are recognized for use with Listed fire doors along the meeting edge of a pair that requires the use of a Category J gasket. The gaskets may be used with steel, wood, or fiberglass faced fire doors. Doors and frames shall be installed per NFPA 80.

Pemko 290_PK, 297_PK, 303_PK, 316_PK, 1842_PK, 2891_PK, 29394_PK perimeter edge gaskets are recognized for use with Listed fire doors along the perimeter edge of the door/frame that requires the use of a Category J gasket.  The gaskets may be used with steel, wood, or fiberglass faced fire doors.  Doors and frames shall be installed per NFPA 80.
  • Category J: Other Gasketing (UL 10C) – e.g., Acoustic Gasket, Weather Seal, etc. [no edge seal or smoke and draft properties]. 
Note: All other requirements and limitations specified in the door or frame listing still apply.

Ratings:
Fire Protection Ratings
Product Configuration Maximum Size Rating
297_PK (MS), 303_PK (MS), 305_N (MS), and 316_PK (MS) Meeting Edge Gaskets Pairs: 8’-0” wide by 10’-0” tall The gasket materials as described in this procedure meets the requirements for a 3 hour positive pressure fire test in accordance with UL 10C, NFPA 252, and CAN/ULC S104.
290_PK, 297_PK, 303_PK, 316_PK, 1842_PK, 2891_PK, 29394_PK Perimeter Edge Gaskets Singles: 4’-0” wide by 10’-0” tall
Pairs: 8’-0” tall by 10’-0” tall

Pemko 297_PK (MS), 303_PK (MS), and 316_PK (MS) meeting edge gaskets are recognized for use with Listed fire doors along the meeting edge of a pair that requires the use of a Category H gasket as part of an air leakage system designed by a registered design professional to meet the 3.0 cfm/ft2 assembly air leakage requirement of NFPA 105.  The gaskets may be used with hollow metal, wood, or fiberglass faced fire doors. The maximum leakage rate at the meeting edge of a pair of doors measured 0.55 scfm/linear foot with hollow metal, wood, or fiberglass faced fire doors.

Air Leakage Ratings 
Test Standard Test Type Rating
UL 1784 Ambient/Elevated Temperature 0.55 scfm/linear foot at 0.10 in. of w.c.
Listing Report Return to Search
Attributes
CriteriaUL 1784 (2015)
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016) Ed. 3 (R:27 May 2021)
CriteriaNFPA 252 (2022)
Fire Resistance3 Hour Category J Gasketing
Fire Resistance20 Min Category J Gasketing
Fire Resistance90 Min Category J Gasketing
Fire Resistance45 Min Category J Gasketing
Fire Resistance60 Min Category J Gasketing
Listing SectionCATEGORY H - SMOKE & DRAFT CONTROL GASKETING
Listing SectionCATEGORY J - GASKETING
Spec ID79998